Product Overview

Floor model axle mounted film holder, selector and dispenser.  Film capacity 112A for 20" or 112A24 for 24" rolls. Designed to be used with belt sealer or with optional hot plate.

Optional Hot Plates:

  • 6” by 15” Hot Plate (112AHP)*
  • 8” by 15” Hot Plate (112A24HP)*

*Recommended to be attached to belt sealer, or lagged to the floor for stability when using hot plate option.

Features
  • Standard 115V Power Supply
  • Solid State Controlled Film Cut Off Rod
  • Heavy Gauge Welded Aluminum Frame
  • Aluminum and Stainless Steel Construction
  • Adjustable Foot Pads for Easy Leveling on Uneven Floors
  • Stainless Steel Wrapping Surface
  • Easy to Use Film Selector Feature
  • Adjustable Film Tension
  • Available in Film Roll Widths - 20" & 24"

Machine Specs & Options

Overall Dimensions: 12 1/2” D, 25” W, 37” H (32 D, 64 W, 94 H cm) -112A
Working Height: 36” (91cm)
Power Requirement: 115 Volt, 6.5 Amp, 60 Cycles
Wattage: 725 Watts
Weight: 43 lbs. (20 kg) -112A

Options
  • 112A: Three 20" Film Roll Capacity
  • 112AHP: Three 20" Film Roll Capacity with 6” by 15” Hot Plate
  • 112AHPS: Stainless Steel Construction, Three 20" Film Roll Capacity, 6” by 15” Hot Plate
  • Stainless Steel Wings (6130-005), 14”W, 22”D, Set of 2
  • 12 Hour Timer ico_question
  • 220 Volt Power Supply

Replacement Parts

SHOP OUR STORE >

Image Part # Description
#1872008 15Amp Toggle Switch, 125V
#6108000 Rectangular Red Pilot Light 125V (Replaces old # 1836002)
#6108003 Fuse Holder, ¼ Quick Disc., HKP-HH (Replaces old # 1821013)
#1818001 Circuit Control Board
#6305018 Bearing Block Set, Table/Floor Model
#6107020 Hot Plate Conversion Assembly for 112A
#6305080 Element Retainer Plate
#3005047 Film Core Axle 5/8" x 24" Long
#1881002 B200 Thermostat
#1851052 5 Foot 16/3 SJT Power Cord with Cap
#1824011 23" Long Cut-Off Rod
#1821034 1 Amp MDA Fuse Slo-Blo
#6110023 White 3" Core Adapter Set
#6110025 3" Aluminum Core Adapter Kit
#6110016 Element Assembly
#6305079 8" x 15" Fabricated Hot Plate
#2145023 B200 Thermostat Knob
#6110040 Seal Plate Wire Harness Kit (3 Wires)

General Questions

What is the standard voltage for wrapping machines?


  • 110V (220V is available.)

Film for Overwrappers


Film for Stretch Film Overwrappers
PVC stretch film for wrapping meat and produce, its chemical characteristics provide barriers to protect the product.
Stretch film for pallet wrap is Polyethylene and not to be used on wrappers.

Film Sizing

Table Top    Floor Model
625A: 18"    104A: 20"
625A Mini: 12"    107A: 19"
600A: 20"    112A: 20"
500A: 20"    102A: 19"
500A Mini: 13"    SM-1: 19"

 


How to properly overwrap packages


USE CAUTION WHEN WRAPPING PACKAGES AS THE CUT-OFF ROD AND PLATE ARE HOT TO THE TOUCH

  1. Place package to be wrapped in the center of the package rest. Using both hands, grasp film at outer edges and with an even, steady, outward motion pull toward yourself enough film to fit over and around the entire package to be wrapped.
  2. Place film over package and tuck under around 2 inches of film along the edge farthest from you. As you tuck the film, begin to pull the package towards you. At this time the package will be enclosed within the film. Please note that when you pull the film towards you that the proper film tension and most of the wrinkles have been removed before sealing package.
  3. Hold turned under film in place and using both hands, place the package on the hot plate to make the first seal. During this step the cut-off rod automatically softens the film so that it will separate from the film roll.
  4. Lift the wrapped package and tuck under the excess film on the sides of the package to make a tight package and then run across the hot plate to make the final seal. Note that the unused film from the roll should be resting on the cut-off rod waiting for the operator to wrap the next package.

View our YouTube video on the setup and operation: http://youtu.be/0eB1YFhg5Eo

 


Energy Saving with 12 Hour Timer


  • The twelve hour timer automatically turns the wrapper off (anywhere from one to twelve hours) after being set.
  • The twelve hour timers help to increase the life of the Heating Elements and other electrical components and conserve energy.
  • The timer itself consumes no additional energy.
  • The twelve hour time replaces the “ON/OFF” switch.

Troubleshooting

Hot plate is smoking


That is excess protective coating on the heating element burning off and should last no more than 10 or 15 minutes.


Hot plate works, but hot rod doesn't


A standard 110V Neon circuit tester can be used for testing.

Hot Rod, Circuit Board and Fuse Holder work together. Hot Plate, Thermostat and Element work together. Hot Plate and Hot Rod are independent of each other.

1) Check the fuse - With the power OFF, disconnect red wire from Terminal 1 and secure it out of the way without touching any metal. With power ON, test across Terminals 3 and 4. If tester does not light, replace fuse.
2) Check the circuit board - With the power OFF, disconnect red wire from Terminal 1 and secure it out of the way without touching any metal. With power ON, test across Terminals 1 and 2. If tester does not light, replace circuit board.
3) Test the Hot rod - With the power OFF, disconnect red wire from Terminal 1 and secure it out of the way without touching any metal. With power ON, test between Terminal 1 and end of disconnected wire. if tester does not light, replace the hot rod.

WHEN REPLACING THE HOT ROD OR CIRCUIT BOARD IT IS RECOMMENDED TO REPLACE BOTH SINCE THEY WORK HAND IN HAND WITH EACH OTHER.

 


Hot rod is not hot enough, or too hot


♦ This unit should NOT be operated if rod temperature exceeds 300 degrees fahrenheit.  If smoke or fumes are detected, discontinue use. ♦

A standard 110V Neon circuit tester can be used for testing.

1) Check the circuit board - With the power OFF, disconnect red wire from Terminal 1 and secure it out of the way without touching any metal. If potentiometer has been adjusted the rod will no longer work correctly. With power ON, test across Terminals 1 and 2. If tester does not light, replace circuit board.
2) Test the Hot rod - With the power OFF, disconnect red wire from Terminal 1 and secure it out of the way without touching any metal. With power ON, test between Terminal 1 and end of disconnected wire. if tester does not light, replace the hot rod.

 


Hot rod is cold


A standard 110V Neon circuit tester can be used for testing.

  1. Check the fuse - With the power OFF, disconnect red wire from Terminal 1 and secure it out of the way without touching any metal. With power ON, test across Terminals 3 and 4. If tester does not light, replace fuse.
  2. Check the circuit board - With the power OFF, disconnect red wire from Terminal 1 and secure it out of the way without touching any metal. With power ON, test across Terminals 1 and 2. If tester does not light, replace circuit board.
  3. Test the Hot rod - With the power OFF, disconnect red wire from Terminal 1 and secure it out of the way without touching any metal. With power ON, test between Terminal 1 and end of disconnected wire. if tester does not light, replace the hot rod.

Machine doesn't turn on


  • Check for loose wires.

Hot plate is cold


Check element then thermostat.

Replace hot plate heating element, if necessary.


Timer will not set for short amounts of time


You must turn knob on the timer past 2 and set back to desired time.

 


Electrical Service Information


Instructions for diagnosing cut off rod, circuit board and fuse issues.  Electrical Service information for table top overwrappers, including part information and electrical testing procedures.

 


Maintenance

Which heating element do I use?


  • The element 6110-016 fits the 6" by 15", 8" by 15" and 9" by 12" hot plates.
  • The 6" by 9" hot plate uses 6504-022 element.

Changing the Non-stick Replaceable Cover


  • The Non-stick Replaceable Cover is not attached.
  • When the unit is cooled down, just pull the cover off.

Schematics & Parts Lists

Non-stick Replaceable Cover: How to prolong the life


The non-stick replacable covers wear with use.
To prolong the life, always keep the cover clean and free of liquid and debris.
Rotate the cover occassionally.
Reduce friction by using an FDA approved lubricant on the cover.